What is contrast between one-shot and repeat mode in A/D conversion?
Latest Updated:03/15/2012
Question:
Is there any difference in the accuracy of the A/D conversion between the one-shot mode, which generates interrupt requests, and the repeat mode, which does not generate interrupt requests?
Answer:
The accuracy of the A/D conversion does not change, regardless of the generation of interrupt requests.